Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Westergren¹ýÀÇ KRCº¯¹ý¿¡ ÀÇÇÑ ESR ÃøÁ¤¹ýÀÇ °ËÅä An Evaluation of KRC modified Westergren Method for Determining Erythrocyte Sedimentation Rate

´ëÇѺ´¸®ÇÐȸÁö 1983³â 17±Ç 4È£ p.417 ~ 425
À±¿ì¼º, ¼­°­¼®, ±è¸í³²,
¼Ò¼Ó »ó¼¼Á¤º¸
À±¿ì¼º (  ) 
°æºÏ´ëÇб³ ÀÇ°ú´ëÇÐ ÀÓ»óº´¸®Çб³½Ç

¼­°­¼® (  ) 
°æºÏ´ëÇб³ ÀÇ°ú´ëÇÐ ÀÓ»óº´¸®Çб³½Ç
±è¸í³² (  ) 
°æºÏ´ëÇб³ ÀÇ°ú´ëÇÐ ÀÓ»óº´¸®Çб³½Ç

Abstract

¿ä ¾à
Á¤»óÀÎ 20´ë ³²ÀÚ 57¿¹¿Í 20´ë ¿©ÀÚ 38¿¹¸¦ ´ë»óÀ¸·Î ÇÑ KRCÀÇ Westergrenº¯¹ýÀÇ Á¤»ó
Âü°íÄ¡´Â 20´ë ³²ÀÚ¿¡ À־ Æò±ÕÄ¡(mean¡¾SD)´Â 5¡¾3.8mm/hrÀÌ°í Á¤»ó¹üÀ§(mean¡¾2SD)
´Â 0-11§®/hr¿´À¸¸ç 20´ë ¿©ÀÚ¿¡¼­ Æò±ÕÄ¡´Â 13¡¾5.1mm/hrÀÌ°í Á¤»ó¹üÀ§´Â 0¡­23mm/hr·Î
¼­ ¿©ÀÚ¿¡¼­ ³ôÀº °æÇâÀ» º¸¿´´Ù.
ÀÔ¿ø ȯÀÚ 74¸íÀ» ´ë»óÀ¸·Î ÇÑ KRC¹ý°ú Wintrobe¹ý°£ÀÇ ESRÄ¡´Â Á¤»ó ¹× slightly
abnormal ¹üÀ§¿¡¼­´Â Wintrobe¹ý¿¡ ÀÇÇÑ ÃøÁ¤Ä¡°¡, moderately abnormal ¹üÀ§ »ó¿¡¼­´Â
KRC¹ý¿¡ ÀÇÇÑ ÃøÁ¤Ä¡°¡ ³ô°Ô ³ª¿ÔÀ¸¸ç hematocrit ±³Á¤ ÈÄ ESRÄ¡ÀÇ ºñ±³¿¡¼­µµ °°Àº °æÇâ
À» º¸¿´´Ù.
KRC ¹ý°ú Wintrobe¹ý°£ÀÇ °Ë»ç¼ºÀû¿¡¼­ ÀÏÄ¡À²Àº Á¤»ó¹üÀ§¿¡¼­´Â KRC¹ýÀÌ, ºñÁ¤»ó¹üÀ§
¿¡¼­´Â Wintrobe¹ýÀÌ °¢°¢ ³ôÀº °æÇâÀ» º¸¿´´Ù.
¸¸¼º¿°Áõ¼º ÁúȯÀÇ screening ¹× ºóÇ÷ÀÌ Àִ ȯÀÚÀÇ ESRÃøÁ¤½Ã¿¡´Â Wintrobe¹ýÀÌ ¸¸¼º
¿°Áõ¼ºÁúȯÀÇ °æ¶óÃßÀûÀ» À§ÇÑ ¸¸¼º¿°Áõ¼ºÁúȯÀÇ °æ°úÃßÀûÀ» À§ÇÑ ESRÃøÁ¤¹ýÀ¸·Î´Â
Westergrenº¯¹ýÀ» ÀÌ¿ëÇÑ KRC¹ýÀÌ ¿ì¼öÇÏ´Ù°í »ý°¢µÈ´Ù.
#ÃÊ·Ï#
The ESR studies have been studied in 57 healthy young men and 38 healthy young
women by KRC modified Westergen method for the normal reference value of ESR in
this laboratory, and also in 74 randomly selected patients for comparison of ESR
between the KRC modified Westergren and Wintrobe method.
The mean value of normal young man was 5¡¾3.8§®/hr and normal range was 0 to 11
§®/hr.
The mean value of normal young woman was 13¡¾5.1§®/hr and normal range was 0
to 23§®/hr.
The mean value and upper limit of range were higher in woman than in man.
In comparison of SSR of patient group, ESR by Wintrobe method was higher in
normal and slightly abnormal group but in moderate abnormal and marked abnormal
levels, ESR by HBC was much higher than that by Wintrobe method.
This result was as same as in comparison of hematocrit-corrected ESR.
The Wintrobe method seemed to be a more reliable method for the screening of
chronic inflammatory conditions, especially having anemia, due to adequate hematocrit
correction.
However for monitoring the progress of chronic inflammatory process such as
rheumatoid arthritis, KRC modified Westergren method appears to be more reliable and
more convenient than Wintrobe method.

Å°¿öµå

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

   

µîÀçÀú³Î Á¤º¸

KCI
KoreaMed
KAMS