Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

ô¼ö¼Õ»ó ȯÀÚ¿¡¼­ À½°æº¸Çü¹°ÀÇ Àå±â ÃßÀû°üÂû Long-term Follow-up for Penile Prostheses in Patients with Spinal Cord Injury

´ëÇѺñ´¢±â°úÇÐȸÁö 1999³â 40±Ç 5È£ p.623 ~ 627
¿Àµ¿Áø, ¹Ú¿øÈñ, ½ÉÈ«¹æ,
¼Ò¼Ó »ó¼¼Á¤º¸
¿Àµ¿Áø (  ) 
Çѱ¹º¸Èƺ´¿ø ºñ´¢±â°ú

¹Ú¿øÈñ (  ) 
ÀÎÇÏ´ëÇб³ ÀÇ°ú´ëÇÐ ºñ´¢±â°úÇб³½Ç
½ÉÈ«¹æ (  ) 
Çѱ¹º¸Èƺ´¿ø ºñ´¢±â°ú

Abstract

°á·Ð
ÀúÀÚµéÀº 1988³âºÎÅÍ 1993³â±îÁö ô¼ö¼Õ»óÀ¸·Î ÀÎÇÑ ¹ß±âºÎÀüÀ¸·Î À½°æ º¸Çü¹°¼³Ä¡¼ú ÈÄ
5³â ÀÌ»ó ÃßÀû°üÂûÀÌ °¡´ÉÇÏ¿´´ø 50¸íÀ» ´ë»óÀ¸·Î Á¶»çÇÏ¿´´Ù. 13¸íÀÇ È¯ÀÚ¿¡¼­ ±¼°îÇü, 35
¸íÀÇ È¯ÀÚ¿¡¼­ Dynaflex, 2¸íÀÇ È¯ÀÚ¿¡¼­ AMS 700 CXMÀ» »ç¿ëÇÏ¿´´Ù. ¼ö¼ú ¼º°ø·üÀº
88%À̾ú°í, º¸Çü¹°¼³Ä¡ ¼ú ÈÄ 5³â°£ ¹ß»ýÇÑ ÇÕº´Áõ ¹ß»ý·üÀº 12·Ê·Î 24%À̾ú°í, ±× Áß °¨
¿°ÀÌ 6·Ê·Î °¡Àå ³ô¾ÒÀ¸¸ç, ±â°èÀû ±â´ÉºÎÀüÀÌ 3·Ê, ¿äµµ¹Ì¶õÀÌ 2·Ê, À½°æÇǺΠ±«»ç°¡ 1·Ê¿´
´Ù.
ô¼ö¼Õ»ó ȯÀÚ¿¡¼­ À½°æ º¸Çü¹°»ðÀÔ¼úÀº ÀÏ¹Ý È¯ÀÚº¸´Ù °¨¿°, ¿äµµ¹Ì¶õ µî°ú °°Àº ÇÕº´Áõ
ÀÇ ¹ß»ý·üÀÌ ³ôÁö¸¸ ¹ß±âºÎÀüÀÇ Ä¡·á, Äܵ¼Ä«Å×ÅÍÀÇ À¯Ä¡, °£ÇæÀû ÀÚ°¡µµ´¢½Ã Æí¸®ÇÔ, ¹Ýº¹
µÇ°í Ä¡·á°¡ Èûµç À½°æÇǺΠ¿­»óÀÇ Ä¡·á¿¡ À¯¿ëÇÑ ¹æ¹ýÀ¸·Î »ý°¢ÇÑ´Ù.

Purpose : Recently the use of penile prostheses in patients with spinal cord
injury(SCI) has been beneficial for sexual dysfunction, maintenance of external devices
and the treatment of penile skin lacerations. We reviewed 50 patients with SCI who had
been followed for more than five years after penile prosthetic Implantation, particularly
in regard to surgical success rate and complication rate.
Materials and Methods : From 1988 to 1993, 102 penile prostheses were implanted in
50 patients with SCI. Penile prosthetic implantation was done for sexual dysfunction in
29 patients and for sexual dysfunction and urinary management in 21 patients. The
types of penile prostheses were malleable in 13 patients, Dynaflex in 35 patients and
AMS 700 CXM in two patients.
Results : We experienced prosthetic infection in six patients, mechanical failure in
three patients, urethral erosion In two patients and penile skin necrosis in one patient.
The overall surgical success rate was 88% and the five-year complication rate was
24%.
Conclusions : Though the complication rate of penile prosthetic implantation in patients
with SCI was higher than in the general population, penile prosthetic implantation
improves the quality of life with regard to sexual function and urinary management in
patients with SCI.

Å°¿öµå

Spinal cord injury; Penile prosthesis; Complication;

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

   

µîÀçÀú³Î Á¤º¸

KCI
KoreaMed
KAMS