Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Ahmed Valve »ðÀÔ¼úÈÄ ¹ß»ýÇÑ °ü(tube)¹Ì¶õ¿¡ ´ëÇÑ ¾ç¸·À̽ļú·Î Ä¡·áÇÑ 2¿¹ Amniotic Membrane Transplantation for Tube Erosion after Ahmed Glaucoma Valve Implant Surgery: Two Cases

´ëÇѾȰúÇÐȸÁö 2003³â 44±Ç 12È£ p.2950 ~ 2954
ÀÌ´ãÈ£, ±èÁظð, ±èÅÂÈ£,
¼Ò¼Ó »ó¼¼Á¤º¸
ÀÌ´ãÈ£ (  ) 
ºñÀü¾È°ú

±èÁظð (  ) 
±¹¸³ÀÇ¿ø·á ¾È°ú
±èÅÂÈ£ ( Kim Tae-Ho ) 
±¹¸³ÀÇ·á¿ø ¾È°ú

Abstract

¸ñÀû : Ahmed valve implantationÈÄ ¹ß»ýÇÑ °ü¹Ì¶õÀ» ¾ç¸· À̽ļú·Î Ä¡·áÇÑ 2¿¹¸¦ º¸°íÇÏ°íÀÚ ÇÑ´Ù.

´ë»ó°ú ¹æ¹ý : Ahmed valve implantationÀ» ½ÃÇàÇÑ ³ì³»ÀåȯÀÚ 2·Ê¿¡¼­ ¹ß»ýÇÑ °ü¹Ì¶õÀ» ½É³¶¸·Æí°ú À¯¸®°á¸· À̽ļúÀ» ½ÃÇàÇÏ°í Ãß°¡·Î ¾ç¸·À̽ļúÀ» »óÇǹæÇâÀ» À§ÂÊÀ¸·Î ÇâÇϵµ·Ï À¯ÁöÇÏ°í ÀÖ´Ù.

°á°ú : ¼úÈÄ 12-14°³¿ù°±îÁö ¹Ì¶õÀÇ Àç¹ßÀº ¾ø¾úÀ¸¸ç ¾È¾Ðµµ ¾ÈÁ¤»óŸ¦ À¯ÁöÇÏ°í ÀÖ´Ù.

°á·Ð : °ü¹Ì¶õÀÇ °æ¿ì ¾ç¸·À̽ļúÀ» Ãß°¡·Î ½ÃÇàÇÔÀ¸·Î½á ¼º°øÀûÀÎ Ä¡·á°á°ú¸¦ ¾òÀ» ¼ö ÀÖ¾ú´Ù.

Purpose: We report two cases of tube erosion after Ahmed valve implantation, treated with Amniotic Membrane Transplantation.

Methods: Erosion of conjunctiva over tube occurred in 2 female patients with Ahmed valve implantation. They were treated with pericardial patch grafts and conjunctival free graft with amniotic membrane epithelial side up transplantation.

Results: No recurrent tube erosion has been found since then. Intraocular pressure has been maintained well for 12-14 months of follow-up.

Conclusions: In cases of tube erosion, additional amniotic membrane transplantation can improve surgical success.