Reliability in Using Routine Coronary CT Angiography with Retrospective Electrocardiographic Gating for the Comprehensive Functional Evaluation of the Left Ventricle

´ëÇÑ¿µ»óÀÇÇÐȸÁö 2019³â 80±Ç 1È£ p.69 ~ 80
°­ÀºÁÖ, È«ÁöÈÆ, ¹ÚÁ¾¹Î, ÀÌÁ¾¹Î,
¼Ò¼Ó »ó¼¼Á¤º¸
°­ÀºÁÖ ( Kang Eun-Ju ) 
Dong-A University Hospital Department of Radiology

È«ÁöÈÆ ( Hong Ji-Hoon ) 
Kyungpook National University Hospital Department of Radiology
¹ÚÁ¾¹Î ( Park Jong-Min ) 
Kyungpook National University Hospital Department of Radiology
ÀÌÁ¾¹Î ( Lee Jong-Min ) 
Kyungpook National University Hospital Department of Radiology

Abstract


Purpose: To evaluate the feasibility of comprehensive left ventricle (LV) functional parameters on routine coronary computed tomographic angiography (CCTA) based on two-dimensional echocardiography (2DE).

Materials and Methods: Ninety-nine patients who underwent CCTA accompanied by 2DE were included in the study. The volumetric LV systolic functional parameters were acquired from 10-phase reconstruction of CCTA data. By differentiating the time-LV volume curve by time domain and measuring mitral valvular orifice areas, transmitral time-velocity curves were drawn and the early (E) to late (A) mitral inflow peak velocities ratio (E/A ratio) was acquired. By measuring a longitudinal jerking velocity of the mitral valvular annulus on a four-chamber view, the mitral peak velocity of early filling (E) to early diastolic mitral annular velocity (E') ratio (E/E' ratio) was evaluated. All functional parameters were compared with the 2DE results.

Results: The LV end diastolic volume, LV end systolic volume, ejection fraction, stroke volume, cardiac output, and LV myocardial mass measured by CCTA and 2DE showed moderate to strong correlations (r = 0.732, 0.821, 0.416, 0.394, 0.328, and 0.764, respectively; p < 0.05). The E/A and E/E' ratios showed strong correlation between CCTA and echocardiography (r = 0.807 and 0.751, respectively; p < 0.05).

Conclusion: When CCTA is performed with retrospective electrocardiographic gating, additional information about the LV function can be acquired as reliably as with echocardiography.

Å°¿öµå

Multidetector Computed Tomography; Echocardiography; Systole; Diastole; Heart Ventricles