±¹³» Àü¸³¼± ÀÚ±â°ø¸í¿µ»ó°Ë»çÀÇ PI-RADS v2 ÃÖ¼Ò ¿ä±¸ Á¶°Ç Áؼö ºñÀ² Á¶»ç Medical Institutions' Adherence to the PI-RADS v2 Minimum Technical Standards for Prostate MRI in Korea

´ëÇÑ¿µ»óÀÇÇÐȸÁö 2019³â 80±Ç 2È£ p.306 ~ 317
±Ç¿µ¿ì, ÃÖ¹®Çü, Á¤½ÂÀº,
¼Ò¼Ó »ó¼¼Á¤º¸
±Ç¿µ¿ì ( Kwon Young-Woo ) 
°¡Å縯´ëÇб³ ÀÇ°ú´ëÇÐ ¼­¿ï¼º¸ðº´¿ø ¹æ»ç¼±°úÇб³½Ç

ÃÖ¹®Çü ( Choi Moon-Hyung ) 
°¡Å縯´ëÇб³ ÀÇ°ú´ëÇÐ ¼­¿ï¼º¸ðº´¿ø ¹æ»ç¼±°úÇб³½Ç
Á¤½ÂÀº ( Jung Seung-Eun ) 
°¡Å縯´ëÇб³ ÀÇ°ú´ëÇÐ ¼­¿ï¼º¸ðº´¿ø ¹æ»ç¼±°úÇб³½Ç

Abstract

¸ñÀû: ÀÌ ¿¬±¸ÀÇ ¸ñÀûÀº ±¹³»ÀÇ ÀÇ·á±â°üµéÀÌ Prostate Imaging-Reporting and Data System version 2 (ÀÌÇÏ PI-RADS v2)ÀÇ ÃÖ¼Ò ¿ä±¸ »çÇ×À» ¾ó¸¶³ª Àß ÁؼöÇÏ´ÂÁö¸¦ ¾Ë¾Æº¸´Â °ÍÀÌ´Ù.

´ë»ó°ú ¹æ¹ý: ÀÌ ¿¬±¸´Â 2015³â 3¿ùºÎÅÍ 2018³â 1¿ù »çÀÌ¿¡ Ÿ ÀÇ·á±â°ü¿¡¼­ ½ÃÇàµÇ¾î º»¿ø¿¡ µî·ÏµÈ Àü¸³¼± ÀÚ±â°ø¸í¿µ»ó°Ë»ç(magnetic resonance imaging; ÀÌÇÏ MRI) Áß ÃÑ 85°³ ±â°üÀÇ 103´ë Àåºñ·Î ½ÃÇàµÈ °Ë»ç¸¦ Æ÷ÇÔÇÏ¿´´Ù. ÀåºñÀÇ ÀÚÀå, ´ëÇк´¿ø ¿©ºÎ, ºñ´¢»ý½Ä±â ¿µ»óÀÇÇаú Àü¹®ÀÇ À¯¹«¿¡ µû¶ó Çʼö ½ÃÄö½º ȹµæ ¿©ºÎ, PI-RADS v2 ÃÖ¼Ò ¿ä±¸ »çÇ× 23 Ç׸ñ¿¡ ´ëÇÑ Áؼö ºñÀ²ÀÇ Â÷À̸¦ Fisher's exact test¸¦ ÀÌ¿ëÇØ ºÐ¼®Çß´Ù.

°á°ú: È®»ê°­Á¶¿µ»ó ȹµæ ¿©ºÎ´Â Àåºñ ÀÚÀå, ´ëÇк´¿ø ¿©ºÎ, ºñ´¢»ý½Ä±â ¿µ»óÀÇÇаú Àü¹®ÀÇ Á¸Àç À¯¹«¿¡ µû¶ó À¯ÀÇÇÑ Â÷ÀÌ°¡ ÀÖ¾ú´Ù. ¿ªµ¿Àû Á¶¿µÁõ°­¿µ»óÀº ºñ´¢»ý½Ä±â ¿µ»óÀÇÇаú Àü¹®ÀÇ°¡ ±Ù¹«ÇÏ´Â ±â°ü¿¡¼­ À¯ÀÇÇÏ°Ô ³ôÀº ºñÀ²·Î ½ÃÇàÇÏ¿´´Ù. PI-RADS v2 ÃÖ¼Ò ¿ä±¸ »çÇ× Áß ¿©·¯ Ç׸ñÀÌ 1.5 T Àåºñ, ºñ´ëÇк´¿ø, ºñ´¢»ý½Ä±â ¿µ»óÀÇÇаú Àü¹®ÀÇ°¡ ¾ø´Â º´¿ø¿¡¼­ À¯ÀÇÇÏ°Ô ³·Àº Áؼö ºñÀ²À» º¸¿´´Ù.

°á·Ð: Àü¸³¼± MRI¿¡¼­ È®»ê°­Á¶¿µ»óÀÇ È¹µæ ºñÀ²°ú PI-RADS v2 ÃÖ¼Ò ¿ä±¸ »çÇ×ÀÇ Áؼö ºñÀ²ÀÌ 3.0 T Àåºñ, ´ëÇк´¿ø, ºñ´¢»ý½Ä±â ¿µ»óÀÇÇаú Àü¹®ÀÇ ¼Ò¼Ó ÀÇ·á±â°ü¿¡¼­ ³ô¾Ò´Ù.

Purpose: To evaluate the adherence rate to Prostate Imaging-Reporting and Data System version 2 (PI-RADS v2) minimum technical standards of prostate magnetic resonance imaging (MRI) in Korean medical institutions.

Materials and Methods: This study included 103 prostate MRI examinations from 85 outside medical institutions performed from March 2015 to January 2018. The difference in adherence rate to minimal technical standards of PI-RADS v2 was compared using a Fisher's exact test between subgroups divided by the magnetic strength of MRI machine, type of medical institution and presence of genitourinary radiologist.

Results: Diffusion-weighted imaging (DWI) was obtained frequently in examinations performed in a 3-T machine, in university hospitals and in medical institutions where genitourinary radiologist work in than the others (p < 0.001, p < 0.001, p = 0.003). Many minimum technical standards of PI-RADS v2 showed significantly lower adherence rate in a 1.5-T machine, in a non-university hospital and in a medical institution without genitourinary radiologist than the others.

Conclusion: The frequency of obtaining DWI and the adherent rate to some of the PI-RADS v2 minimum technical standards were significantly higher in 3-T machines, university hospitals and medical institutions with a genitourinary radiologist.