Àá½Ã¸¸ ±â´Ù·Á ÁÖ¼¼¿ä. ·ÎµùÁßÀÔ´Ï´Ù.

Clinical Efficacy of Real-Time Sonoelastography for the Follow-Up of Congenital Sternocleidomastoid Muscle Torticollis

´ëÇÑ¿µ»óÀÇÇÐȸÁö 2020³â 81±Ç 1È£ p.176 ~ 189
Á¤¹Ì¸®, ÀÌÀμ÷, ½Å¿ë¹ü, ¼ÛÀ¯¼±, ¹Ú¼¼°æ, ¼ÛÁ¾¿î, ¹®ÁøÀÏ,
¼Ò¼Ó »ó¼¼Á¤º¸
Á¤¹Ì¸® ( Jeong Mi-Ri ) 
Pusan National University Hospital Department of Radiology

ÀÌÀμ÷ ( Lee In-Sook ) 
Pusan National University Hospital Department of Radiology
½Å¿ë¹ü ( Shin Yong-Beom ) 
Pusan National University Hospital Department of Rehabilitation Medicine
¼ÛÀ¯¼± ( Song You-Seon ) 
Pusan National University Hospital Department of Radiology
¹Ú¼¼°æ ( Park Se-Kyoung ) 
Kosin University Gospel Hospital Department of Radiology
¼ÛÁ¾¿î ( Song Jong-Woon ) 
Inje University Haeundae Paik Hospital Department of Radiology
¹®ÁøÀÏ ( Moon Jin-Il ) 
Gyeongsang National University Changwon Hospital Department of Radiology

Abstract


Purpose: To evaluate the clinical efficacy of real-time sonoelastography (RTS) for the follow-up of congenital muscular torticollis, based on measurements of muscle elasticity.

Materials and Methods: Thirty-four infants (23 male, 11 female) with congenital sternocleidomastoid (SCM) muscle torticollis underwent ultrasonography and elastography between November 2012 and December 2014. We evaluated the thickness, morphology (mass-like, fusiform, or overall thickened shape), and echogenicity of the SCM muscle on grayscale images and color patterns (homogeneous blue, mixed green < 50% and ¡Ã 50%, and green to red) on elastography. Strain ratios were measured using Q-lab software. A clinician classified the degree of neck rotation and side flexion deficits using a 5-point grade system based on angles of neck rotation and side flexion. Correlations between the ultrasonography and clinical findings were evaluated by statistical analysis.

Results: Twenty-two infants had right and 12 had left SCM torticollis, respectively. Linear regression analysis showed that involved/contralateral SCM thickness differences, morphology, elasticity color scores, and strain ratios of the affected SCM muscles were significantly correlated with neck rotation and side flexion deficit scores (p < 0.05). The elasticity color score of the affected SCM muscle was the most significant factor.

Conclusion: RTS might provide a reliable means for evaluating and monitoring congenital muscular torticollis.

Å°¿öµå

Index terms Ultrasound; Sonoelastography; Muscles; Torticollis; Infant

¿ø¹® ¹× ¸µÅ©¾Æ¿ô Á¤º¸

 

µîÀçÀú³Î Á¤º¸

KCI
KoreaMed
KAMS