ÀçÁúÀÌ ´Ù¸¥ µÎ ½Ç¸®ÄÜÇÏÀ̵å·Î°Ö ÄÜÅÃÆ®·»ÁîÀÇ Âø¿ë¿¡ µû¸¥ ·»Áî Àü¸éÀÇ ºñħÀÔ¼º TBUT ºñ±³ Comparing Pre-Lens Non-invasive TBUT with Two Different Silicone Hydrogel Contact Lens Materials

´ëÇѽðúÇÐȸÁö 2019³â 21±Ç 1È£ p.89 ~ 98
±èÁ¤¹Ì,
¼Ò¼Ó »ó¼¼Á¤º¸
±èÁ¤¹Ì ( Kim Jeong-Mee ) 
±Øµ¿´ëÇб³ ¾È°æ±¤Çаú

Abstract

¸ñÀû : ÀçÁúÀÌ ´Ù¸¥ µÎ Á¾·ùÀÇ ÇÑ´Þ Âø¿ë ½Ç¸®ÄÜÇÏÀ̵å·Î°Ö ·»Á Âø¿ë ±â°£¿¡ µû¶ó ·»Áî Àü¸éÀÇ NITBUT¿ÍÀÚ°¢Àû Áõ»óÀ» ºñ±³ÇÏ¿´´Ù.

¹æ¹ý : Samfilcon A¿Í Comfilcon A ·»Á 32¸í(Æò±Õ 23.5¡¾2.92¼¼, ¿©: 24¸í, ³²: 8¸í)ÀÇ ¿À¸¥ÂÊ ´«°ú ¿ÞÂÊ ´«¿¡ °¢°¢ Âø¿ëÇÏ°í, ´ë»óÀÚ¿¡°Ô 3ȸ ¹æ¹® (ù° ³¯ 3½Ã°£ ÈÄ, 1ÀÏ ¹× 1ÁÖÀÏ ·»Áî Âø¿ë 9½Ã°£ ÈÄ)À» ¿äûÇÑ ÈÄ, °í´ëºñµµ(100%)¿Í Àú´ëºñµµ(10%) ½Ã·ÂÇ¥¸¦ ÀÌ¿ëÇÑ ½Ã·Â°Ë»ç¿Í Keratograph 5M (Oculus, Germany)À» »ç¿ëÇÏ¿© ·»Áî Àü¸éÀÇ non-invasive tear breakup time (NITBUT)¸¦ ÃøÁ¤ÇÏ¿´´Ù. ÄÜÅÃÆ®·»Áî¿Í °ü·Ã ÀÖ´Â ÀÚ°¢Àû Áõ»óÀº 5°³ Ç׸ñ(ºÒÆíÇÔ, °ÇÁ¶°¨, ½Ã·Â º¯È­, ´« °¨°í ½ÍÀ½, ·»Áî Á¦°ÅÇÏ°í ½ÍÀ½)À¸·Î ¼³¹®Áö ÀÛ¼ºÀ» Çϵµ·Ï ÇÏ¿´´Ù.

°á°ú : ¹àÀº Á¶¸í»óÅ¿¡¼­ °Ë»çÇÑ °í´ëºñ½Ã·Â°ú Àú´ëºñ½Ã·Â, ±×¸®°í ·»Áî Àü¸éÀÇ NITBUT´Â Samfilcon A¿ÍComfilcon A »çÀÌ¿¡¼­ À¯ÀÇÇÑ Â÷ÀÌ°¡ ³ªÅ¸³ªÁö ¾Ê¾Ò°í, °¢°¢ÀÇ ·»Áî Âø¿ë 7ÀÏ µ¿¾È ½Ã·Â°ú NITBUT º¯È­¿¡¼­µµ ÀǹÌÀÖ´Â Â÷ÀÌ´Â ¾ø¾ú´Ù. ÄÜÅÃÆ®·»Áî Âø¿ë°ú °ü·ÃµÈ 5°³ Ç׸ñÀÇ ÀÚ°¢Àû Áõ»óÀÇ »ó´ëÀû ¹ß»ýºóµµ´Â ¸ðµç Ç׸ñ¿¡¼­ À¯ÀÇÇÑ Â÷ÀÌ°¡ ¾ø¾ú°í, ·»Áî¿¡ ´ëÇÑ ¼±È£µµ¿¡¼­µµ µÎ ·»Áî Âø¿ëÀÚµéÀÇ ¹ÝÀÀÀº Åë°èÀûÀ¸·Î Â÷ÀÌ°¡ ¾ø¾ú´Ù(°¢°¢, 40.6%, 37.5%).

°á·Ð : ÀÌ ¿¬±¸´Â Samfilcon A¿Í Comfilcon A»çÀÌ¿¡¼­ pre-lens NITBUT¿Í ÀÚ°¢Àû Áõ»ó¿¡ ´ëÇÑ ºñ½ÁÇÑ ÀÓ»ó °á°ú¸¦ º¸¿©ÁØ´Ù. µÎ ½Ç¸®ÄÜÇÏÀ̵å·Î°Ö ·»Áî´Â Á¦Á¶»ç¿Í ·»Áî ÀçÁúÀÌ ´Ù¸§¿¡µµ ºÒ±¸ÇÏ°í ·»Áî Âø¿ëÀÚµé »çÀÌ¿¡¼­ µÎ ·»ÁîÀÇ Â÷ÀÌÁ¡Àº ¹ß°ßÇÒ ¼ö ¾ø¾ú´Ù.

Purpose : To compare pre-lens non-invasive tear break-up time(NITBUT) and subjective ocular symptoms with two different silicone hydrogel lens materials.

Methods : Samfilcon A and Comfilcon A lenses were worn on the right and left eyes of 32 (23.5¡¾ 2.92 years, female: 24, male: 8), respectively. After Each subjects attended three visits (on day 1 after 3 hours: on days 1 and 7 after 9 hours of wear), visual acuity using high (100%) and low (10%) contrast chart and pre-lens NITBUT using Keratograph 5M were measured. The subjects were surveyed with questionnaire for subjective ocular symptoms in terms of discomfort, dryness, changeable vision, closing eyes and removing lenses.

Results : High and low contrast visual acuity, and pre-lens NITBUT values were not significantly different between Samfilcon A and Comfilcon A. There was no significant difference in visual acuity and NITBUT change during 7 days of wearing each lens. The relative frequency of subjective symptoms of 5 items related to wearing contact lenses was not significantly different in all items, the responses of the wearers in terms of lens preference were not statistically different (40.6%, 37.5%, respectively).

Conclusion : The study demonstrates similar clinical results for pre-lens NITBUT and subjective ocular symptoms with Samfilcon A and Comfilcon A. The two silicone hydrogel lenses could not find the difference between the two lenses in the lens wearer despite difference lens materials and manufacturers.

Å°¿öµå

½Ç¸®ÄÜÇÏÀ̵å·Î°Ö ·»Áî; ·»Áî Àü¸é NITBUT; ÀÚ°¢Àû Áõ»ó
Silicone hydrogel contact lens; Pre-lens NITBUT; Subjective ocular symptoms